Sterile Flocked Nylon Swab with 80mm Breakpoint

Sterile Flocked Nylon Swab with 80mm Breakpoint

Sterile Flocked Nylon Swab with 80mm Breakpoint.

Flocked swabs consist of nylon fibres to provide not only excellent sample collection but also release of that sample into Transport media.

The term “flocked” refers to a process of attaching fibers of variable length flocking to a surface coated in the adhesive in order to enhance sample collection.

Flocked swabs provide advantages for a variety of specimen collection procedures employed by medical and laboratory professionals. The swab is designed to be ergonomic for the user as well as for patient comfort and to optimize sample collection.

The flocked nylon fibers act similar to a fine bristled brush, which creates thousands of contact points whereby, cells, microscopic organisms or particles may be collected. Sterile flocked swabs are the preferred choice when collecting samples from the nasal cavity.

Nasal Swab flocked swab with 80mm breakpoint

Nasal Swab flocked swab with 80mm breakpoint

Get Latest Price

Email:flockedswabs@gmail.com

Product parameters.

Nasopharyngeal swab, 80 mm

100 swabs per package

Application type – nasopharynx

sterile

Nylon flocking tip. ABS plastic shaft

Needle tip diameter length: 2.5cm; Width 1 mm; The total length of the swab is 15 cm

Medical Swab Test Kit specimen collection sterile nylon flocked swab

Medical Swab Test Kit specimen collection sterile nylon flocked swab

Sterile Flocked Nylon Swab performance and structure.

Composed of a swab head (flocked nylon plush head) and a polystyrene plastic rod.

Sterile (micro) plastic rod nylon flocked swab (separately packaged) for nasopharynx.

For one-time use and sterilized by radiation.

It is suitable for DNA sampling, nasopharynx and other parts of the sample collection, convenient transmission, avoid pollution.

Name: nylon flocked swab for nasopharynx, plastic rod, aseptic independent packaging.

This product is produced by new technology in Australia. A large number of clinical trials abroad show that compared with ordinary sterile swabs, nylon flocking swabs have better collection and transportation effects on clinical biological samples, especially for those samples that cannot be submitted for inspection in time and placed for too long.

Flocked Nylon Swab Advantage:

1. Connection strength: when the moving speed of the fixture of the tensile testing machine is 200 mm / min; The pull-out force between the sampling head and one end of the connecting rod shall not be less than 2n,

2. Breaking strength: when the test span is 6cm, the swab shall be able to withstand 4N axial static pressure for 15s without permanent deformation or fracture phenomenon.

3. Rotational friction degree: spray nylon fluff on the ABS rod after viscose. The rubbing fastness refers to that the test is not greater than 2n, the rotational friction is not less than 3 times at 360 degrees, and the amount of nylon fluff on the surface is not greater than 2.

The sterile disposable sampling flocked swab has passed the whole project testing by the national quality supervision instrument testing centre, and the qualified test report zc1011965 / 96 / 97 has been issued.

The sampling swabs are divided into pharyngeal swabs, oral swabs, DNA swabs and cervical swabs, which can be used by various laboratory testing centres.

The sampling flocking swab is three times higher than the traditional winding swab in the number of samples collected and released and does not cause damage to the cell sample, so as to ensure the survival rate of the cell sample, no residual fatty acids, no impact on the test and detection effect, and no harm to the human body.

*Nasal swab for medical institutions to collect virus and DNA samples infected in the patient’s nasal cavity;

Sterile Flocked Nylon Swab application

Sterile Flocked Nylon Swab application.

*Type an oral swab for medical institutions to collect virus and DNA samples of patients with oral and throat infections;

oral swab

oral swab.

Flocked Tip Swab

Flocked Tip Swab

Flocked Tip Swab| China Flocked Swab Factory and Manufacturers.

Detection of viral nucleic acid sequence based on reverse transcription polymerase chain reaction (RT-PCR) is the main means for large-scale screening of new coronary pneumonia.

Generally, nucleic acid detection technology has the characteristics of early diagnosis, high sensitivity and specificity.

And it has the advantages of sample collection and preservation, personnel operation, nucleic acid extraction.

The performance of the kit is the cause of false negative or false positive test results.

Flocked swabs are the main samples for PCR. In the selection of raw materials, flocked glue plays a key role in the collection and release efficiency of swabs. Whether to use high-quality aqueous flocking glue is the main factor affecting the water absorption and hydrophilicity of fluff. The experiment is to compare the sample collection effects of swabs flocked with different glues.

What is a flocked tip swab?

The top of the flocking swab is a nylon fiber structure.

Nylon fibers are deposited on the surface of plastic rod in a certain direction by electrostatic field to form brush layer.

The layers are completely parallel and perpendicular to the inner rod surface.

Flocked tip swab brush head can effectively collect samples.

Flocked tip swab factory Product advantages.

The flocked swab can completely capture the cell sample through the directional friction effect of the brush fiber layer.

The capillary movement between the nylon fibers at the front end of the flocking swab can form a strong hydraulic pressure for absorbing liquid or cell line samples.

Cell samples can also be evenly and neatly concentrated on the near surface of brush fibers, so more than 95% of the samples can be released finally.

Cell Medical (Dongguan) Co., Ltd.  has many years of experience in medical application molding and flocking treatment heads and swabs.

Our flocked swabs are famous for their stable and reliable performance and excellent absorption and elution ability.

Cell medical (Dongguan) Co., Ltd. Daily production of millions of flocked sampling swabs

Cell medical (Dongguan) Co., Ltd. Daily production of millions of flocked sampling swabs. flocked tip swab 

COVID-19 Testing:PCR swab test,antibody test, and antigen test difference

COVID-19 Testing:PCR swab test,antibody test, and antigen test difference

COVID-19 Testing :PCR swab test,antibody test, and antigen test difference.

PCR swab test(Nucleic acid test) and antibody / antigen detection are important means to confirm COVID-19, and also one of the important processes for patients to diagnose. But do you know what their detection principle is? What are the sample types? What is the inspection process and what are the problems? 

COVID-19 nucleic acid test

Nucleic acid detection has the characteristics of early diagnosis, high sensitivity and specificity. At present, real-time fluorescence quantitative RT-PCR is the most widely used technology. PCR swab testing is a very effective way to identify SARS-COV-2.

1. Principle of COVID-19 test kits?

The researchers used sampling swabs to collect samples of the virus, targeting the unique gene sequence of the virus.

By PCR amplification of the virus sample, the target DNA sequence we selected increased exponentially.

Researchers can combine the amplified DNA sequence with pre added fluorescent labeled probe fragments to generate fluorescent signals.

The more target genes amplified, the stronger the cumulative fluorescence signal.

In Virus-free samples, no target gene was amplified. Therefore, researchers can not detect enhanced fluorescence signals.

That is, we do not carry COVID-19.

Therefore, nucleic acid detection is actually to detect the accumulation of fluorescence signal to determine whether there is viral nucleic acid in the sample.

COVID-19 test kits_PCR swab test(Nucleic acid test)

COVID-19 test kits_PCR swab test(Nucleic acid test)

 

2. What are the methods of covid-19 testing samples?

Generally, PCR nasal swab test, pharyngeal swab, nasopharyngeal swab, sputum, bronchial lavage fluid, alveolar lavage fluid, etc.

Sampling swab consists of a nylon flocked swab.what is a flocked swab?

3. Steps of PCR swab test for COVID-19.

At present, pharyngeal swabs are the main sampling method for the diagnosis of novel coronavirus infection. Correct sampling is the key to improve the accuracy of nucleic acid samples collected from pharyngeal swabs. What are the factors affecting the accuracy of nucleic acid samples collected from pharyngeal swabs? There are three main aspects:

Depth of throat swab collection?

How long is the throat swab in contact with the mucosa?

Pharyngeal swab sampling “dot to dot” or wipe?

 

(1) Oral and pharyngeal swab collection tips

1. Sampling position: sit or semi-sit in decuffine position, with head slightly raised and mouth open, and head resting on the wall or against the back of the chair.

2. Standard sampling operation: Sampling personnel press the tongue of the subject with tongue depressors.

Pharyngeal swabs should be performed on both sides of the pharyngeal tonsil with “Quick wipe up and down” and on the posterior pharyngeal wall with “Quick left and right wipe” . Repeat 3 to 4 times.

Avoid contact with tongue, teeth and gums.

If you feel uncomfortable, quit, take a break, and try again.

Oropharyngeal Sampling flocked swab diagram

Oropharyngeal Sampling flocked swab diagram

3. Precautions: Drinking water before oral and pharyngeal swab test will dilute the virus attached to the pharynx, especially drinking hot water will inhibit the activity of the virus.

In order to improve the accuracy of pharyngeal swab nucleic acid detection, we recommend that subjects do not drink water 15-30 minutes before the detection, so as to ensure the high accuracy of pharyngeal swab nucleic acid test.

 

(2) Nasopharyngeal swab collection tips

1.The sampling personnel shall collect samples from the side of the subject, and the subject shall pull down the mask to expose only his nostrils. If there is sneezing reflex, the subject can cover it with elbow or paper towel.

nasopharyngeal sampling diagram

nasopharyngeal sampling diagram

2. Standard sampling operation: “one insertion, two stops and three rotations” — measure the distance from the tip of the nose to the front of the ear, half of the insertion length, usually about 4 cm for adults; Stay for 15-30 seconds to absorb nasopharyngeal secretions (depending on tolerance, minimum stay for at least 3 seconds; Rotate the nasopharyngeal swab for 1 week and slowly remove it.

The above is for the reference of sampling medical staff and patients, let’s work together to defeat COVID-19!

(3)Store samples

Dip the flocked swab head into the cell preservation solution(Virus transport medium), and tighten the tube cap immediately after breaking the tail;

Storage, put the sample tube into a sealed bag for timely inspection, and the inspection process requires a strict transportation environment, 2-8 ℃ storage.

(4) PCR TEST

Researchers operate nucleic acid extraction, extract inactivated virus samples for subsequent nucleic acid detection, and can use automatic equipment such as nucleic acid extractor.

Fluorescence PCR nucleic acid detection, that is, on the machine detection, the extraction of fluorescence PCR amplification reaction, needs 70-80 minutes.

process pcr test

process pcr test

4. What are the problems in nucleic acid testing?

False negative, due to improper sampling, improper specimen preservation, the use of different types of specimens and the use of different manufacturers of reagents may lead to nucleic acid test results “false negative” and missed diagnosis;

■ High requirements for detection equipment or platform, high sensitivity RT-PCR instrument is expensive, laboratory cleanliness and operator requirements are also high;

■ Nucleic acid testing is time-consuming. It usually takes 4-6 hours to complete an RT-PCR test.

Therefore, when the nucleic acid test is negative.

Relevant personnel can increase the detection of IgM and IgG antibodies to make up for the shortcoming that nucleic acid detection is easy to cause missed diagnosis.

 

COVID-19 Testing serum antibody test

Seven days after novel coronavirus pneumonia, the serum specific antibodies gradually emerged. The first is immunoglobulin IgM antibody, and then IgG antibody.

Thus, an elevated IgM antibody indicates a recent acute infection, and an elevated IgG antibody indicates a previous infection.

The biggest advantage of serological testing lies in its convenience and short detection time, which can effectively break through the limitations of existing detection technology on personnel and sites and shorten the detection time.

Novel coronavirus infection can be diagnosed in suspected cases if the serum specific IgM and IgG antibodies are positive, the IgG antibody changes from negative to positive, or the recovery period increases by 4 times or more than the acute period.

antibody test sampling process_COVID-19 Testing

antibody test sampling process_COVID-19 Testing

1. Principle of serum antibody test kit?

The sample is added to the sample adding hole, and the sample will move forward along the detection card under the action of chromatography.

If the sample contains new coronavirus IgM antibody, the antibody will combine with colloidal gold labeled virus antigen to form a sandwich complex, which will show a positive result.

If the sample contains New Coronavirus IgG antibody, the antibody will bind to colloidal gold labeled New Coronavirus antigen and form a sandwich complex, which will show positive results.

The detection card also contains a quality control line (line C) to judge whether the chromatography process is smooth.

2. What are the sample types for serum antibody detection?

Generally, it is blood, including serum, plasma and whole blood.

3.COVID-19 antibody test in three steps

1. Open the aluminum foil bag of the test card, take out the test card and place it horizontally on the table;

2. Use a pipette to absorb serum/plasma/whole blood sample and add it to the sampling site. Then use the same method to absorb buffer drops and add them to the sampling hole of the test card.

3. Wait 15 minutes and read the result.

4. What are the problems in serum antibody detection?

■ False positive, individual patients with rheumatoid factors in the blood, heterosinophilic antibodies, autoantibodies, drugs and tumor cells, etc., easy to cause cross-reaction test, so occasionally false positive results;

■ False negative, due to the existence of a certain window period of serum antibody detection methods and the sensitivity of the detection kit will appear false negative results.

Therefore, serum antibody test is only used as a supplementary test for suspected cases of novel Coronavirus nucleic acid negative test and cannot be used as a diagnostic indicator for screening alone.

The combined use of serum antibody detection and nucleic acid detection can help to improve the detection rate of the disease and find out the confirmed patients as much as possible, which is more conducive to the control of the epidemic.

Interpretation of results of nucleic acid combined with IgG and IgM antibody detection

COVID-19 Testing antigen detection

A novel coronavirus antigen test can novel coronavirus be detected directly in human body samples. The diagnosis is fast and accurate, with low requirements for equipment and personnel.

antigen test kit_SARS-CoV-2

antigen test kit_SARS-CoV-2

1. Principle of antigen detection kit?

SARS-CoV-2 , N, E and S protein antigens stimulate virus cells to produce specific antibodies.

2. What are the types of antigen test samples?

Usually samples from infected sites, e.g. oropharyngeal swabs, nasopharyngeal swabs, sputum, serum, plasma, etc.

 

3.COVID-19 antigen test in four steps

1. Drop the sample treatment liquid into the sample treatment tube;

2. Stir the sample swab and squeeze the tube wall until the specimen is fully eluted into the treatment solution;

3. Take out the detection card and add sample to the round hole;

4. Wait 15 minutes and read the result.

4. What are the problems in antigen detection?

■ False negative, higher sensitivity of antigen detection is required. Because New Coronavirus mainly affects alveolar and other lower respiratory tract. Therefore, sampling from the upper respiratory tract of nasopharynx and oropharynx cannot determine whether the pathogen can be detected. Or the sample contains a small number of viruses. All these factors may cause missed detection.

■ The preparation process is tedious and time-consuming. The development of the antigen kit requires the preparation of the recombinant antigen first, and then the preparation of monoclonal antibody in mice, which takes about two or three months. If the prepared antibody performance is not good, it needs to be prepared again, which takes another two or three months.

The joint detection

The COVID-19 Testing nucleic acid / antibody / antigen has different focuses and can not be substituted for each other. Multiple detection methods are combined and complement each other. Combine molecular biology and immune level detection to give play to their respective advantages and improve sensitivity and specificity. It can effectively shorten the detection window period, improve the positive detection rate, and provide double guarantee for all possible risk groups.

 

reference:Zhengtu Li,Yongxiang Yi et al. Development and clinical application of a rapid IgM‐IgG combined antibody test for SARS‐CoV‐2 infection diagnosis. J Med Virol.2020;1-7

Mini flocked nose swab china factory and manufacturers

Mini flocked nose swab china factory and manufacturers

Mini flocked nose swab china factory and manufacturersCell medical (Dongguan) Co., Ltd.,  flocked swab adopts vertical nylon fiber, which has stable and reliable performance and good adsorption and elution ability. Flocked swabs optimize sample collection and elution into the transmission medium. The swab also has a molded breakpoint that allows you to safely and easily disconnect the cotton swab. Our company provides multiple breakpoint options for different pipes.We can customize swab mold, swab packaging, sterile packaging and swab OEM services.

Mini flocked nose swab Specifications

Mini flocked nasal swab

Mini flocked nasal swab

 

  • Swab Length: 145mm±5mm
  • Flocked Tip Length: 8mm
  • Swab Tip Diameter: 8mm±0.2mm
  • Breakpoint: 80/90mm
  • Packing: Individual Sterile Package
  • Certificate: CE/FDA/ISO
  • OEM/ODM: Support
  • GMP Factory: YES
  • Supplying Ability: 500,0000pcs/ day

 

Application: Nasopharyngeal Sampling Swab

Mateiral: 100% Medical Grade Nylon

Sterilization: EO

Certificate: ISO13485, CE, FDA, SGS, MSDS, TDS.

What’s the use of a flocked nose swab

Nasal swab detection is a kind of nucleic acid detection, which is used to detect the presence of viral nucleic acid in the body. So as to determine whether the human body infected with COVID-19.

Nasal swab detection requires collecting cells deep in the throat of the tested person and placing them in a Petri dish for observation. Because New Coronavirus is mainly transmitted through the respiratory tract,if the human body is infected with COVID-19, there will be a lot of viruses in the throat. Therefore, it is a more accurate way to detect the existence of COVID-19 by detecting the cells in the throat.

What is the method of mini nasal swab collection?

① Please keep the patient’s head still and remove the secretions on the surface of the anterior nostril;

② use a flocked swab or other tools to the distance from the nostril to the root of the ear and mark it with your fingers;

③ insert the swab gently and slowly through the nasal cavity;

④ swab until the finger mark or stay for several seconds after encountering resistance to absorb secretions; (generally stay for 15-30 seconds, and then rotate gently for 3 times);

⑤ gently rotate the swab and put it into the virus sampling tube (transport medium); Break the swab tail rod along the breaking point and place it completely in the tube. Tighten the pipe cover.

⑥ If you need to collect from two nostrils, you should use another swab.

⑦ Send to the inspection room for inspection as soon as possible.

⑧ Note the information of the collected person to avoid confusion.

Mini flocked nasal swab sampling display

Mini flocked nasal swab sampling display

Nasal mini-tip flocked swab

Nasal mini-tip flocked swab

Nasal mini-tip flocked swab Medical Nasopharyngeal swab

Nasopharyngeal swabs are a means of detection. Doctors use nasopharyngeal swabs mainly for special bacterial group infection or virus infection in the nasopharynx. They will use sterile pharyngeal swabs to enter the nasopharynx and throat through the nasal cavity and wipe the mucosa. Conduct bacterial culture, virus culture and drug sensitivity test to determine our treatment plan and diagnosis. This examination is a non-invasive examination.

Product description

medical nasal nasopharyngeal mini tip flocked swab

1. EO sterile, individual packing
2. With molded breakpoint
3. Ergonomic and anatomic design, easy to use
4. Perpendicular nylon fibers, increased assay sensitivity

CM-96000 NASAL SWAB

CM-96000 NASAL SWAB

Product Flocking swab for nasal
Item No CM-96000
Material Tip: 100% nylon, handle: plastic (ABS)
Usage Single use for Nasopharyngeal excretion collection
Size Diameter: 3mm

Length: 150mm
Breaking point: 80mm

Packing 1pc/pouch, 10000pcs/ctn
sterile, individual packing cm-96000 Packaging picture

sterile, individual packing cm-96000 Packaging picture

Nasal mini-tip flocked swab Packaging & Delivery

Packaging Details
Individual Sterile Package
100 pcs/zip pouch
5000pcs /carton box
Carton Size: 52*40*30 cm
G./W.: 6.5kg
Port
shenzhen

Contact us

  • Cell medical (Dongguan) Co., Ltd.
  • E-mail:flockedswabs@gmail.com
  • No. 98, Wusha street, Chang’an Town, Dongguan City, Guangdong Province, China
  • Web:www.swabmanufacturer.com/
Iclean nylon flocked swab

Iclean nylon flocked swab

Iclean nylon flocked swab

Product purpose:

Iclean nylon flocked swab is ideal for bacteriological sample processing, virological cell culture, DFA test, rapid and direct test, enzyme immunoassay test, polymerase chain reaction and molecular diagnosis based test, as well as forensic identification.

For throat sampling of respiratory viruses such as influenza, swine influenza, avian influenza, hand, foot and mouth.

Iclean nylon flocked swab,View more

Iclean nylon flocked swab,View more

Characteristics of sampling swab products:

1. It has extraordinary water absorption capacity, which can increase the number of samples collected on its surface from 20% of traditional sampling swabs to 60%.

2. The release rate of the collected samples is more than 90%, so as to ensure the high reliability of the results.

3. Different preservation solutions were selected for different specimen types.

4. The plastic rod has a unique breakable design to facilitate specimen transportation.

5. Ethylene oxide sterilization, irradiation sterilization, independent packaging.

Iclean gene sampling series flocking DNA oral test pieces are specially used to improve the amount and quality of genomic DNA in oral test piece cells. Oral cell sample is a good non-invasive collection and detection method instead of blood. Combined with icleanhcy’s series of DNA separation and stabilization kits, it can quickly collect high-purity and complete DNA samples.

DNA flocking swab is suitable for human and animal use. It has advantages over other DNA samples in design. Its unique sample matrix and rapid release interface are more conducive to efficient cell collection and maximize DNA yield. The test piece has been sterilized with ethylene oxide and passed the detection of human DNA contamination.

characteristic

The unique test substrate greatly improves the yield of DNA;

Adult oral SWAB piece 1 to 10 μ g DNA;

It is a good alternative to blood collection;

Both human and animal can use it;

Simple and fast operation;

There are two types of single and double disinfection packaging to choose from;

application;

Genotype study;

Veterinary genotyping and diagnosis;

Parent child and genetic services;

Forensic and DNA population studies;

About us

Cell medical (Dongguan) Co., Ltd. produce flocked swabs, VTM kits, virus transport medium, with multiple automatic production lines.We support custom production, OEM and so on, and develop products with customers.

Email:flockedswabs@gmail.com

Disposable virus sampling kits

Disposable virus sampling kits

Disposable virus sampling kits

Cell medical (Dongguan) Co., Ltd. _China swab manufacturer.Our flocked swabs are famous for their stable and reliable performance and excellent absorption and elution ability.

We produce flocked swabs, VTM kits, virus transport medium, Disposable virus sampling kits,with multiple automatic production lines.We support custom production, OEM and so on, and develop products with customers.

Email:flockedswabs@gmail.com

Nasopharyngeal Swab & Oropharyngeal Swab

Item No.# Description Sterilization
CM-98000 Oropharyngeal Specimen Collection flocked Swab, Single swab packaging, Sterile,Breakpoint 30mm EO
CM-96000 Nasopharyngeal Specimen Collection flocked Swab, Single swab packaging, Sterile,Breakpoint 80mm EO
CM-93050 Throat Specimen Collection flocked Swab, Single swab packaging, Sterile,Breakpoint 80mm EO
CM-96000N Nasopharyngeal Specimen Collection flocked Swab, Single swab packaging, Sterile,Breakpoint 90mm EO
CM-98000T Medical Flocked Swab With Test Tube, with Individually Wrapped and Sterile Buccal(oral)  Swabs EO
CM-93050T Specimen Collection Swab tube, Individual Sterile Package Oropharyngeal Swabs EO
CM-96000T Nasal Sample Collection Kits,flocked Swab With Test Tube,ndividually Wrapped and Sterile EO

Ethylene oxide sterilization, irradiation sterilization and independent packaging.

Supply Ability:500,000-1,000,000 Pieces per Month

Disposable sampling swab application

The top of the flocked swab is made of nylon fiber. The nylon fiber is successively attached to the surface of the medical ABS rod through the electrostatic field. The layer is completely parallel and perpendicular to the surface of the internal rod for DNA collection.

The collection system adopts nylon flocked swab, which is non-toxic to microorganisms and can maximize the collection and release of samples.

A large number of clinical experiments show that compared with ordinary sterile cotton swab, nylon flocking swab has better effect on the collection and transportation of clinical microbial samples

This is especially true for those specimens that cannot be submitted for examination in time and placed for too long.

Our flocked swabs are famous for their stable and reliable performance and excellent absorption and elution ability.

Product features

1.Non invasive,Non-irritating;

2.Outstanding sample collection and release ability;

3.Rapid Absorption;

4. Increased Assay Sensitivity;

5.Perpendicular Nylon Fibers;

6.Certified Free Of Inhibitors And Interference.

Our FDA & CE certificate can ensure effective and legal customs clearance in your country.

VTM (Viral Transport Medium):Including inactivated and non inactivated.

Quality Certification:MSDS,CE,ISO

Our virus transport medium is based on Hanks equilibrium salt solution (HbSS).

It contains calcium and magnesium, heat inactivated fetal bovine serum, gentamicin and amphotericin B.

The composition and preparation of virus vectors follow the recommendations of who and CDC.

The product is provided in a sterile 13 ml flat bottom tube with or without swabs, providing the greatest range of possibilities for collecting samples.

Inactivated Viral Transport Medium(ITM).

This product is designed for the inactivation of a variety of viruses, such as clinical 2019-ncov, influenza, avian influenza, hand-foot-mouth, measles virus, norovirus, rotavirus and other virus specimens, and for the transportation of the virus nucleic acids. It is compatible with various viral nucleic acid extraction kits available on the market and can achieve seamless connection with downstream nucleic acid extraction.

1. It can not only inactivate the virus, but also prevent nucleic acid degradation.

2. Room temperature transmission

3. The samples can be stored at room temperature for 20 days.

4. It is used to collect, store and transport viruses, chlamydia, mycoplasma and Ureaplasma.

Model Specification
VTM-B-CM010120S 2With Nasal flocked Swab& Throat Swab ;  1ml inactivated medium ;2ml tube
VTM-B-CM010111S With Nasal Swab ; 1ml inactivated medium ;2ml tube
VTM-B-CM010112S With Throat Swab ; 1ml inactivated medium ;2ml tube
VTM-B-CM020220S 2With Nasal Swab& Throat Swab ;  2ml inactivated medium ;5ml tube
VTM-B-CM020211S With Nasal Swab ; 2ml inactivated medium ;5ml tube
VTM-B-CM020212S With Throat Swab ; 2ml inactivated medium ;5ml tube
VTM-B-CM020320S 2With Nasal Swab& Throat Swab ;  3ml inactivated medium ;5ml tube
VTM-B-CM020311S With Nasal Swab ; 3ml inactivated medium ;5ml tube
VTM-B-CM020312S With Throat Swab ; 3ml inactivated medium ;5ml tube
VTM-B-CM040320S 2With Nasal Swab& Throat Swab ;  3ml inactivated medium ;10ml tube
VTM-B-CM040311S With Nasal Swab ; 3ml inactivated medium ;10ml tube
VTM-B-CM040312S With Throat Swab ; 3ml inactivated medium ;10ml tube
VTM-B-CM040520S 2With Nasal Swab& Throat Swab ; 5ml inactivated medium ;10ml tube
VTM-B-CM040511S With Nasal Swab ; 5ml inactivated medium ;10ml tube
VTM-B-CM040512S With Throat Swab ; 5ml inactivated medium ;10ml tube

Non inactivated Viral Transport Medium(ITM).

Application:Nucleic acid detection and virus isolation.

1. Low temperature non freezing storage, does not damage the shell of the virus, and is convenient for long-distance transportation.

2. Applicable to all kinds of swab samples, including oral swab, nasal swab, throat swab, etc

3. It can be used for H1N1 influenza virus and any other virus that can be sampled with a swab.

4. The viral nucleic acid can be extracted with the lentivirus DNAOUT or the lentivirus RNAOUT.

5. Antibiotics in the sampling solution can effectively prevent bacterial and fungal contamination.

6. Bovine serum albumin is added to the sampling solution, which can protect the virus sample and improve the separation rate.

Model Specification
VTM-A-CM010120S 2With Nasal flocked Swab& Throat Swab ;  1ml Non inactivated medium ;2ml tube
VTM-A-CM010111S With Nasal Swab ; 1ml Non inactivated medium ;2ml tube
VTM-A-CM010112S With Throat Swab ; 1ml Non inactivated medium ;2ml tube
VTM-A-CM020220S 2With Nasal Swab& Throat Swab ;  2ml Non inactivated medium ;5ml tube
VTM-A-CM020211S With Nasal Swab ; 2ml Non inactivated medium ;5ml tube
VTM-A-CM020212S With Throat Swab ; 2ml Non inactivated medium ;5ml tube
VTM-A-CM020320S 2With Nasal Swab& Throat Swab ;  3ml Non inactivated medium ;5ml tube
VTM-A-CM020311S With Nasal Swab ; 3ml Non inactivated medium ;5ml tube
VTM-A-CM020312S With Throat Swab ; 3ml Non inactivated medium ;5ml tube
VTM-A-CM040320S 2With Nasal Swab& Throat Swab ;  3ml Non inactivated medium ;10ml tube
VTM-A-CM040311S With Nasal Swab ; 3ml Non inactivated medium ;10ml tube
VTM-A-CM040312S With Throat Swab ; 3ml Non inactivated medium ;10ml tube
VTM-A-CM040520S 2With Nasal Swab& Throat Swab ;  5ml Non inactivated medium ;10ml tube
VTM-A-CM040511S With Nasal Swab ; 5ml Non inactivated medium ;10ml tube
VTM-A-CM040512S With Throat flocked Swab ; 5ml Non inactivated medium ;10ml tube
Disposable virus sampling kits sampling process

Disposable virus sampling kits sampling process

Nasopharyngeal swab sampling_flocked swabs

Nasopharyngeal swab sampling_flocked swabs

Oropharyngeal swab sampling

Oropharyngeal swab sampling

Nasal swab for flu

Nasal swab for flu,Rapid antigen nasal or throat swab

Nasal swab for flu_Rapid antigen (nasal or throat swab) test

Influenza is common in winter and spring. The clinical manifestations are mainly systemic poisoning symptoms such as high fever, fatigue, headache, cough and systemic muscle pain, while the respiratory symptoms are mild.

Influenza viruses are prone to mutation, infectious, susceptible to population and high incidence rate. They have caused many outbreaks in the world, and are important public health issues worldwide.

Why should we detect and prevent influenza?

According to the World Health Organization (WHO), seasonal influenza can cause 3-5 million severe cases and 290000-650000 deaths worldwide every year.

The researchers believe that children under the age of 5 are at high risk of severe influenza, but children under the age of 2 are at the highest risk, and infants under 6 months have the highest hospitalization rate and mortality.

Pregnant women, infants, the elderly, patients with chronic basic diseases and other high-risk groups have a higher risk of serious diseases and death after suffering from influenza.

Nasal swab for flu : common influenza test method

Nasopharyngeal sample collection

Nasopharyngeal sample collection

Influenza is an acute inflammation of the respiratory tract caused by the patient’s infection with influenza virus. The patient can have a series of symptoms such as cough, expectoration, fever, sore throat, stuffy nose, runny nose and general fatigue. In case of influenza, we should conduct relevant examinations in time to further clarify the diagnosis, including the following tests:

First, blood routine test, patients with influenza can promote the increase of lymphocytes. If combined with bacterial infection, there can be the increase of leukocytes and so on.

Second, scientists can culture throat swabs of influenza viruses. In throat swab culture, researchers can detect the related virus.

Third, influenza patients can do second-generation sequencing, including sputum second-generation sequencing, which can determine the type of virus infected.

Fourth, influenza patients can do the detection of respiratory pathogens to further clarify the pathogens of infection.

At present, the two most common influenza tests are rapid antigen diagnostic test  and influenza virus cell culture test. Both tests rely on Nasopharyngeal swabs, pharyngeal swabs, etc. for virus sampling. The most commonly used sampling swab is nylon flocking swab.

Nasal swab for flu:Application

It is suitable for the detection and sampling of COVID-19, influenza virus , hand foot mouth disease virus, COVID-19, measles rubella and other types of viruses.

About nasal swab sampling

Why use flocked nylon swabs?

flocked swabs_Cell medical (Dongguan) Co., Ltd.

flocked swabs_Cell medical (Dongguan) Co., Ltd.

Flocked nylon swab: excellent sample collection / release ability, release rate > 90%.

Conventional fiber swab: the sample is intercepted by the gap in the fiber mass. That is, the sample is penetrated, diluted and intercepted in the fiber.  Acquisition is slow and release is slower.

The sampling time of flocked swab is 3-5 seconds, while that of traditional swab is 15-120 seconds or even longer.

This caused pressure on the staff during the diagnosis process. Only by extracting samples faster can we complete the collection and analysis more efficiently.

Precautions for patients with nasopharyngeal swab:

① Please do not take antibiotics a few days before making nasal swabs;

② Do not use disinfectant mouthwash or smear the focus a few hours before nasal swab.

③ Do not eat, smoke or drink a few hours before doing nose swab.

Precautions for Sampler:

① . the sampler shall stand on the side of the patient for sampling.

② The patient is required to pull down the mask to expose only his nostrils. In case of sneezing reflex, the patient can cover it with elbows or paper towels.

If the sampler is not directly in front of the patient, the exposure risk will be lower.

③ If the patient’s turbinate is hypertrophic, the nasal tract is narrow, and the insertion of the nasal swab feels resistance. Try to change one side of the nasal cavity or directly change to oropharyngeal swab collection.

④ Those with nasal allergy symptoms are easy to induce sneezing. It is recommended to take oropharyngeal swab samples.

⑤ Remember to wear a protective mask / screen. For individuals who are highly suspected or basically diagnosed, or who have severe cough and hiccup, they should put on protective clothing.

⑥ After sampling, replace gloves, disinfect hands, and spray disinfectant where patients have touched.

Finally, we should pay attention to nasal swab for flu in special times. Remember to wear masks and personal hygiene when going out. Once you find the virus, please isolate it to avoid re transmission.

 

What is a sterile swab

What is a sterile swab?

Sterile swab is the full name of disposable sterile sampling swab. The sterile sampling swab does not contain or other live microorganisms. Common sterilization methods include autoclave, EOS (ethylene oxide gas) and γ-ray irradiation. In medicine, we usually use sterile swabs for biological sample collection.  Such as bacterial sample processing, COVID-19, nasal swab sampling, throat swab sampling, oral swab sampling, virological cell culture and so on are ideal ways.

Swabs are sterile to maintain the integrity of the sample. Usually, there is a resealable sterile container or bag to preserve the integrity during processing and transportation to the laboratory. Many different people use sterile cotton swabs, including medical personnel, food manufacturers and crime scene investigators.

Sterile swabs can be used to collect samples. The material, size and shape of the sterile swab head may be different, such as round or pointed. Traditional swab may be made of cotton fiber, polyester or calcium alginate.  Collection and publishing volumes are large and may be corrupted. Traditional swab laboratory staff also need to use scissors to cut, which is too troublesome and time-consuming.Our new flocked disposable sampling cotton swab greatly reduces the time cost and has the advantage of being easier to use than traditional swabs.

The main advantages of our sterile flocked swab are as follows.

1. It has extraordinary water absorption capacity and can increase the number of samples collected on the watch from 20% of the traditional sampling swab to 60%.

2. The release rate of collected samples exceeds 90%, which ensures the high reliability of the results.

3. Select different preservation solutions for different types of samples.

4. The plastic rod has a unique fragile design, which is convenient for sample transportation.

5. Ethylene oxide sterilization, irradiation sterilization and independent packaging.

Sampling operation method.

1.Nasopharyngeal swab sampling.

Nasopharyngeal Sampling diagram

Nasopharyngeal Sampling diagram

①Insert a sterile swab into the nostril of the patient,reaching the surface of the posterior nasopharynx.

②Swab over the surface of the posterior nasopharynx. Hold the swab in the nosefor15-30s and rotate it 3 times.

③Withdraw the sterile swab from the nasal cavity.

④Put virus sampling tube vertically.

⑤At the breaking point, disconnect the swab, discard the tail, and completely place the swab into the tube.

⑥Tighten the tube cap, mark it, put it into the biosafety bag and seal it.

2.Oropharyngeal swab sampling

Oropharyngeal Sampling diagram

Oropharyngeal Sampling diagram

① Keep the head slightly tilted, the mouth open, and the pharyngeal tonsils on both sides exposed.

②The sampling personnel shall wipe the root of the tongue with a swab. Wipe the pharyngeal tonsils on both sides of the subject back and forth with a strong force for at least 3 times, and then wipe the posterior pharyngeal wall up and down for at least 3 times.

③Put the sampled swab into the virus sampling tube, break the swab rod at the mouth of the tube cover and completely put it into the tube.

④Tighten the tube cap, mark it, put it into the biosafety bag and seal it.

⑤Submit for inspection in time.

Anal swab sampling

Anal Sampling diagram

Anal Sampling diagram

①The patient is in the knee chest position or lateral position.

② Gently insert a sterile cotton swab into the anus for 3cm-5cm, and then gently rotate and pull it out.

③Immediately put it into a 15ml outer screw cap sampling tube with 3ml-5ml virus preservation solution.

④Fold off the tail of the cotton swab, tighten the sealing cover, and then submit it for inspection in time.

⑤In order to avoid embarrassment of the examinee, anal swab sampling is generally conducted in a more private place, and the operation requirements of anal swab sampling are more strict. Generally, there will be no obvious discomfort after anal swab sampling.

 

Nasopharyngeal swab collection kits with virus transport media

Nasopharyngeal swab collection kits with virus transport media

Nasopharyngeal swab collection kits with virus transport media

Cell medical (Dongguan) Co., Ltd.

Nasopharyngeal swab collection kits are used to collect nasopharyngeal swab samples,which is a high quality and reasonable kit for testing COVID-19 .

The collection kit contains virus transport media, which can collect, transport and store viruses at room temperature The ability of these kits to detect samples by RT-PCR has been verified. The virus and related samples shall be stored and transported within 48 hours under cold storage (2 ~ 8 ℃).

Characteristics of nasopharyngeal swabs and virus transport tubes.

The sterile nasopharyngeal swab we provide has a flocked tip swab with a breakpoint located about 80-90 mm from the tip, which is compatible with the catheter provided. The virus sampling tube cap design is very effective in containing media and preventing sample leakage.And these sampling tubes are pre labeled, and each tube has a unique bar code identifier.

Nasopharyngeal swab collection kits with virus transport media

Nasopharyngeal swab collection kits with virus transport media

Product specification

A) 1pcs flocked swab ,1 pc 10ml tube with 3ml medium refilled;
B) 2pcs flocked swab ,1 pc 10ml tube with 3ml medium refilled;
C) 1pcs flocked swab ,1 pc 5ml tube with 2ml medium refilled;
D) 2pcs flocked swab ,1 pc 5ml tube with 2ml medium refilled;

certification

• CE IVD registration Kit;

• iso13484 certified manufacturer, registered with FDA;

 

Related products

Contact us

Cell medical (Dongguan) Co,Ltd.

  • skype:+8618814476009
  • E-mail:flockedswabs@gmail.com
  • No. 98, Wusha street, Chang’an Town, Dongguan City, Guangdong Province, China